Ampio CAN modules tag


M-REL-10s: Module with ten relay outputs

Module M-REL-10s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has ten relay outputs, ten ground-detecting inputs and a 1-Wire interface. It also supports the functionality of a controller for the roller shutters and blinds' drives.

Last update September 8, 2023, tags: Ampio CAN modules, REL family, DIN rail modules, Input modules, Output modules, Relay outputs, Lights, Roller shutters and blinds, Wall switch

M-REL-C4s: Module with four relay outputs

Module M-REL-C4s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has four relay outputs and four ground-detecting inputs. It also supports the functionality of a controller for the roller shutters and blinds' drives.

Last update September 8, 2023, tags: Ampio CAN modules, REL family, DIN rail modules, Input modules, Output modules, Relay outputs, Lights, Roller shutters and blinds, Wall switch

M-REL-8s: Module with eight relay outputs MROL-8s Discontinued

Module M-REL-8s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has eight relay outputs, eight ground-detecting inputs and a 1-Wire interface. It also supports the functionality of a controller for the roller shutters and blinds' drives.

Last update September 8, 2023, tags: Ampio CAN modules, REL family, DIN rail modules, Input modules, Output modules, Relay outputs, Lights, Roller shutters and blinds, Wall switch

M-SERV-3s: Remote system management and IP integrations module Discontinued

Module M-SERV-3s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The M-SERV-3s module is a communication gateway for Ampio mobile applications - both within the local network and via the Ampio Cloud platform - plus, it enables IP integrations.

Last update September 7, 2023, tags: Ampio CAN modules, SERV family, Wall switch, Sensors, Dallas 18B20, Input modules, Output modules, Relay outputs, DIN rail modules, Integrations, Lights, Ampio Cloud, IP, Mobile app, Hotel, Node-RED, Roller shutters and blinds, LoRa

M-DOT-9: 9-fields touch panel module

Module M-DOT-9 is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has nine sensor fields and a 1-Wire interface. Sensor fields The touch panel sensor fields are capacitive buttons located behind the glass pane, which is the front of the module.

Last update March 7, 2023, tags: Ampio CAN modules, DOT family, Sensors, Dallas 18B20, Input modules, Wall switch, Touch panels, Personalisation

M-LED-s: Ampio lighting bus controller

Module M-LED-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module acts as an OWA lighting bus controller. OWA lighting bus The OWA lighting bus (One Wire Ampio) is a solution dedicated to controlling LED lighting.

Last update January 12, 2023, tags: Ampio CAN modules, LED family, DIN rail modules, Output modules, Dimmer, LED lights, Lights, OWA lighting

M-OC-C8s: Module with eight OC outputs and an RGBW controller functionality

Module M-OC-C8s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has eight OC outputs, four ground-detecting inputs and supports the functionality of an RGBW lighting controller.

Last update December 5, 2022, tags: Ampio CAN modules, OC family, Integrations, Output modules, DIN rail modules, Lights, LED lights, RGBW lights, Open-collector drivers, Central heating, Security, Wall switch

M-SERV-MINI-s: Remote system management and IP integrations module

Module M-SERV-MINI-s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The M-SERV-MINI-s module is a communication gateway for Ampio mobile applications - both within the local network and via the Ampio Cloud platform - and enables IP integrations.

Last update October 4, 2022, tags: Ampio CAN modules, SERV family, Output modules, DIN rail modules, Integrations, Ampio Cloud, IP, Mobile app, Node-RED, Open-collector drivers, Central heating

M-CON-WL-p: Ampio LoRa base station module

Module M-CON-WL-p is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module acts as a base station for wireless modules that communicate using the Ampio LoRa technology

Last update July 27, 2022, tags: Ampio CAN modules, CON family, Junction box modules, LoRa

M-OC-4s: Module with four OC outputs and an RGBW controller functionality MRGBWOC-4s

Module M-OC-4s is a component of the Ampio system. Required voltage to power the module is 11 — 16V DC. The module is controlled via CAN bus. The module has four OC outputs and supports the functionality of an RGBW lighting controller.

Last update July 13, 2022, tags: Ampio CAN modules, OC family, Output modules, DIN rail modules, Lights, LED lights, RGBW lights, Open-collector drivers, Central heating